Home / Learn / Particle Size Testing: Sieve, Air Jet Sieve, Laser Diffraction and 3D Imaging

Particle Size Testing: Sieve, Air Jet Sieve, Laser Diffraction and 3D Imaging

Four ways to measure particle size, what each one sees, and when each one is the right tool.

Key takeaways

  • A rotary tapping sieve shaker (Ro-Tap style) is the classic mass-based method, and many specs are written in its language.
  • An air jet sieve uses a rotating air jet and vacuum to pull fines through one screen, so it handles fine and cohesive powders that blind a shaker stack.
  • Laser diffraction reads a whole distribution in minutes but reports an equivalent sphere and cannot tell length from width.
  • 3D dynamic image analysis photographs each particle in several orientations, so it reports length, width and thickness.
  • The methods measure different things, so numbers will not match exactly. Pick one and stay consistent.

Why measure particle size at all

Size decides dissolution, flow, mouthfeel, dust and blend behavior. A spec such as “through 100 mesh” or “D90 under 80 µm” only means something if it is measured the same way every time. See how to read a powder spec for the numbers themselves.

Rotary tapping sieve shaker

A stack of sieves with progressively smaller openings is loaded with a weighed sample and shaken by a machine that combines a horizontal circular motion with vertical taps. The action copies hand sieving, and it keeps reorienting particles so they can find the openings. After a set time, the powder left on each screen is weighed. The result is the percent of mass retained at each size.

  • Strong at: coarse to medium powders, quick pass or fail checks against a mesh spec, irregular shapes, and results anyone can audit by weighing. Standard machines run from several inches down to about 635 mesh (20 µm).
  • Watch for: fine or cohesive powders that clump and blind the screens, fragile particles that break from the tapping, and run time and sample size. Keep them the same every test.

Air jet sieve

An air jet sieve tests one screen at a time. A slotted nozzle rotates under the screen while a vacuum draws air through it. The jet lifts and disperses the powder, breaks up soft clumps, keeps the mesh clear, and pulls particles smaller than the openings down through the screen. You weigh what remains and repeat on the next screen.

  • Strong at: fine, light and cohesive powders that tend to agglomerate. Typical instruments cover roughly 10 to 20 µm up to about 4 mm, runs are often only a few minutes, and the method is gentle because it needs no mechanical sieving aids. Below about 40 µm it is the usual dry method.
  • Watch for: one screen per run, so a full distribution takes several runs, and very light or fragile material can lift off or break.

Laser diffraction

A laser beam passes through dispersed powder, and the scattering pattern is converted into a volume-based size distribution. It reads the whole curve in minutes and reaches into the sub-micron range. See how it works.

  • Strong at: the full distribution, D10, D50 and D90, fast and repeatable, and very fine powders.
  • Watch for: it reports the size of an equivalent sphere, so it cannot tell length from width, and dry or wet dispersion changes the answer.

3D dynamic image analysis

Particles fall past a light source and cameras that photograph them in flight. Because each particle tumbles and is imaged many times in different orientations, the software can measure its length, width and thickness, plus shape descriptors such as aspect ratio and roundness. A single flat image cannot do that, because one particle is only seen from one side.

  • Strong at: rods, flakes, crystals and irregular particles, anything where shape drives flow or dissolution, and it compares well with sieve results when width is used.
  • Watch for: it is slower than laser diffraction because many particles must be imaged, and it covers tens of microns up into millimeters rather than the finest sub-micron powders.

Which one should you use?

Use the rotary tapping sieve shaker. Pass or fail against a mesh spec, easy to verify by weighing, and it is the language many specs use.

Use the air jet sieve for the cut that matters, or laser diffraction for the whole curve. A shaker stack blinds on cohesive fines.

Use laser diffraction. It gives D10, D50, D90 and span, and shows a second peak that a sieve stack would miss.

Use 3D dynamic image analysis. It reports length, width and thickness separately, so you can see why a rod-shaped or flaky powder behaves differently from a round one.

Why the numbers differ

A sieve sorts by the smallest opening a particle can pass, which is mostly a measure of its width. Laser diffraction turns scattered light into a sphere and cannot separate length from width, so for non-round particles it usually gives a broader distribution than imaging or sieving. 3D image analysis measures each dimension directly, which is why it lines up best with sieve results when width is chosen. The practical answer is to correlate your methods once on your own material, then use the same method for every lot.

How the methods fit together

  1. Screen at the line. Sifting and mesh checks keep oversize out of a batch. See centrifugal sifting.
  2. Check the cut. A sieve shaker or air jet sieve confirms the top size.
  3. Read the curve. Laser diffraction shows the full distribution and tails.
  4. Look at the particles. 3D imaging shows length, width and shape when shape matters.
  5. Record it. The same method, sample size and time on every lot, so trends mean something.
Sieve analysis is free for NutraShore customers. We run rotary tapping sieve analysis across the full range of standard sieve sizes. Send a sample. To convert sieve numbers, use the mesh to micron converter.
A stack of sieves shakingA stack of four sieves with decreasing openings above a pan, shaken so each size fraction stays on its own sieve.Coarse sieveMedium sieveFine sieveFiner sievePan (fines)Sample inWeigh what stays on each sieve. Illustration only.
A stack of sieves shaking. Illustration only.

Quick answers

What is the difference between a sieve shaker and an air jet sieve?

A rotary tapping sieve shaker moves a whole stack of screens at once. An air jet sieve tests one screen at a time and uses a rotating air jet and vacuum to pull fines through, so it works better on fine and cohesive powders.

Why do sieve and laser results differ?

A sieve mostly measures particle width. Laser diffraction reports the size of an equivalent sphere and cannot tell length from width, so for non-round particles it tends to show a broader distribution.

What is 3D dynamic image analysis?

A method where particles fall past a light and cameras, and each one is photographed many times in different orientations. The software then reports length, width and thickness, plus shape measures.

Which method is best for a quick mesh spec check?

A rotary tapping sieve shaker. Pass or fail against a mesh number is simple, auditable and matches how many specs are written.

Does NutraShore offer sieve analysis?

Yes. Sieve analysis is free for our customers, and we also run air jet sieve, laser diffraction and 3D image analysis.

Have a project?

We mill, blend, sift, granulate and test. Tell us what you need.

Request a quote