Home / Learn / Powder Properties: How to Read a Particle Size and Density Spec

Powder Properties: How to Read a Particle Size and Density Spec

The numbers you argue about on a certificate of analysis, explained.

Five numbers that decide whether a powder works

  • Particle size distribution. A distribution, not a single number. One figure hides both tails.
  • Bulk versus tapped density. How much of a powder is air, and how much it settles.
  • Friability. How readily a granule breaks back into fines during handling. A granule that survives the bag but not the auger solved nothing.
  • Wettability. Not the same as solubility. A soluble powder can still float, clump and refuse to disperse.
  • Hygroscopicity. Milling creates new surface area, and more surface means faster moisture pickup and caking in the drum.

Reading a particle size spec

One conversion is worth memorizing: double the mesh, halve the microns.

MeshOpening
50300 µm
100150 µm
20075 µm
40038 µm

These are the real US sieve openings, not approximations. More holes per inch means smaller holes. Use the full mesh to micron converter for other sizes.

What the D-numbers mean

  • D50: half the material is finer and half coarser. A median, not an average and not a maximum.
  • D90: 90% is finer than this. The coarse tail, where grit complaints come from.
  • D10: 10% is finer than this. The fine tail, where dust and flow problems come from.
Same D50, different distributionsA tight and a wide distribution curve centered on the same D50.same D50TightWideParticle size, µm (log scale). Same D50. Very different powder.
Same D50, very different powder. Illustration only.

How to read a laser diffraction result

Every particle size report puts this plot in front of you. The top chart shows how much material sits in each size band. The line below is cumulative: at any size, the share of the sample that is finer.

  • The numbers come off the line. Find 50% on the vertical axis, run across to the curve, then drop down to the size. That is D50. Repeat at 10% and 90%.
  • Span is the width: (D90 minus D10) divided by D50. Under about 1.5 is tight. Over 3 is broad, and the tails will misbehave.
  • Two peaks is a finding. A second hump means two populations: agglomerates, a contaminant, or a blend that never blended.

In the worked example, D10 is about 6 µm, D50 about 22 µm and D90 about 82 µm, so the span is 3.5. See how the measurement is made in laser diffraction.

Bulk density decides what fits in the box

Poured versus tapped powderThe same mass of powder occupies less volume after tapping because air between particles is squeezed out.PouredTappedsame mass
Poured versus tapped. Illustration only.

You buy powder by weight, but every process downstream handles it by volume. Bulk density is mass per unit volume including the air between particles. A poured powder is typically 40 to 60% empty space.

  • Hausner ratio is tapped density divided by bulk density. Under 1.25 flows freely. Over 1.40, expect bridging.
  • Flodex measures flow directly: the smallest orifice, in millimeters, the powder falls through unaided. Lower is better.

Why it costs money

  • Freight and warehousing. You ship and store cubes, not kilos. Double the bulk density and the same tonnage takes half the pallets.
  • Package and capsule fit. A bottle or capsule is a fixed volume. Too light and the dose will not fit.
  • Fill accuracy. Augers and dosators meter by volume, so lot-to-lot density drift becomes fill-weight drift.
  • Segregation. Large density differences between components separate on every transfer and truck ride.
Reading a laser diffraction resultA size histogram above a cumulative undersize curve with D10 6, D50 22 and D90 82 micrometers marked.Volume in each size bandCumulative undersize, %0255075100D10 6 µmD50 22 µmD90 82 µm123581220305080120200300500800Particle size, µm (log scale). Worked example, span 3.5.
Size histogram and cumulative curve with D10, D50 and D90. Illustration only.

Quick answers

What do D10, D50 and D90 mean?

They are the sizes below which 10%, 50% and 90% of the material falls. D50 is the median, D10 describes the fine tail and D90 the coarse tail.

What is a good Hausner ratio?

Under 1.25 usually flows freely. Over 1.40 usually means bridging problems in hoppers.

How do I convert mesh to microns?

Double the mesh and the opening roughly halves: 100 mesh is 150 microns and 200 mesh is 75 microns. The converter on this site lists the full table.

Have a project?

We mill, blend, sift, granulate and test. Tell us what you need.